REC ROOM TECHNICAL SPECIFICATIONS:
SOUND:                                                               
SPEAKERS:
• 2 SUBS- EAW SB180P (Floating from ceiling above stage left and right)
• 2 MAINS-EAW JF560E (Mounted next to subs)
• 1 DELAY- EAW UA42 (Floating from ceiling about ½ way back on the west side)
• 1 ROUTING SWITCHER- Knox RS 4x4
• 1 POWER CONDITIONER- Power Werks 1501E
• 1 CROSSOVER- Ashly XR1001

SUB/MAIN/MONITOR/DELAY AMPS
• 1 QSC RMX 2450 (Mains)
• 1 QSC RMX 4050 (Subs)
• 1 QSC RMX 1450 (Monitors)
• 1 QSC RMX 1450 (Delay)
• 1 AUTO-MIX SOUND MIXER- LM-3204 Stereo Line Mixer

Installed in control room
• 2 auto-mix mic-level channels using installed sound board
• Use snake to patch to portable board in concert hall

1 16-CHANNEL SNAKE
• 16 mic-level channels to send signal from installed auto-mix board to portable concert board
• 2 Main XLR returns, 2 Monitor returns

PORTABLE SOUND BOARD- Mackie CR-1604
1 COMPACT 5 DISC CHANGER- Technics SL-PD687

7 MONITOR SPEAKERS
• 2 EAW SM-122E
• 4 Renkus-Heinz-TRX-121/9W; 500w/8ohm

PLEASE NOTE:
• Speaker monitors, microphones, and various accessories can be provided for an additional cost

LIGHTING:
STAGE
• Circuit breakers for stage lights are located in the PL-5 electrical panel on south wall of the control room
• Circuit breakers 1, 3, 5, 7, 9, & 11 control the stage lights
• PORTABLE LIGHTING BOARD- NSI (MC 7016)
• 2 DIMMER PACKs – NSI DDS6000 controlled through multiplex, 8 dimmable channels, 1000 watts per channel
• Light levels controlled by portable lighting console patched from control room snake panel

HOUSE
• Florescent or neon lights controlled at light switches on northeast wall by the reception counter

VIDEO:
• 1 LCD PROJECTOR- Epson Powerlite 820p
• 1 VGA SWITCHER- Kramer VP 32XLN- 3 VGA sources in with audio, 2 mirrored VGA out
• 1 CD/DVD PLAYER- Sony DVP-NS325
• 2 VHS DECKS-
• 1 Sharp VC-A592
• 1 Sharp VC-A992
• 1 VHS DECK- Mitsubishi HS-U530
• 1 PROJECTION SCREEN- Da-Lite 10 x 10

ELECTRICAL:
Minimum one week notice required—PLNU electrician must supervise
• 1 120 VOLT 20 AMP CIRCUIT- on wall
• 1 208/120 VOLT 3-PHASE 4-WIRE Y CONNECTED, 200 AMP FUSED DISCONNECT    

NC-146-1.jpg

NC-146-2.jpg

NC-146-3.jpg

Contact: Email Media to report problems with gear, please NOTE ROOM NUMBER and BE SPECIFIC.
Email Help Desk to report problems that are computer-related.
Visit the Media Services Link for questions about policy, reserving additional gear, or to schedule training.
Use the Master Calendar to reserve this room or check on its availability.